MINISART RC15 Syringe Filter 0.2 um. 50/Pkg ยี่ห้อ Sartorius
รหัสสินค้า : 17761 K
ราคา |
3,959.00 ฿ |
จำนวนที่จะซื้อ | |
ราคารวม | 3,959.00 ฿ |
สินค้าไม่เพียงพอ
สินค้าหมด
Minisart® RC15 Syringe Filter 17761----------K, 0.2 µm Regenerated Cellulose
Minisart® RC with hydrophilic regenerated cellulose (RC) is optimized for aqueous liquids and solvents with a pH of 3 - 14 and is stable against DMSO. Type 17761 with a pore size of 0.2 µm can be used for sample preparation and has a male luer slip outlet. Version K is a non-sterile pack of 50. Units can be sterilized by autoclaving or EO.
Item no.: 17761----------K
Availability (ex works): On Request
Non-sterile Minisart® RC syringe filters are supplied in a pouch in one pack. This reduces waste and makes the handling easier whenever the application allows clarification under non-sterile conditions, like this is the case for the majority of sample preparation steps prior to HPLC or GC analysis. The RC membrane is the best option for reliable and leachable free filtration. The very low non-specific binding characteristics of this membrane makes it a perfect choice for aqueous samples and solvents. In addition, unlike PVDF filters, those with RC membranes are suitable for DMSO and other amides, or for ketones, esters, and ethers. The housing of the filter is made of PP (polypropylene) which is compatibility with harsh solvents, acids and bases.
- A pouch in one pack for less waste
- Minimum extractables or leachables
- Very low non-specific binding
- Outperforming chemical compatibility
Bubble Point
- Min. value with water 3.0 bar (44 psi)
Burst Pressure
- Min. value 7.0 bar (102 psi)
Connector Inlet
- Female Luer Lock
Connector Outlet
- Male Luer Slip
Delivery Condition
- Non-Sterile
Device Type
- Syringe Filters
Filtration Area
- 1.7 cm²
Flow Rate
- 20 mL/min with water at 1 bar (14.5 psi) | 55 mL/min with methanol at 1 bar (14.5 psi)
High Flow
- No
Hold-up Volume
- 30 – 100 µL before bubble point
Housing Dimensions
- 25 × 23 mm
Housing Material
- Polypropylene (PP)
Maximum Allowable Working Temperature
- 121 °C (250 °F)
Maximum Operating Pressure
- 4.5 bar (65 psi)
Membrane Material
- Regenerated cellulose (RC)
Non-Fiber Releasing
- This filter product complies with the title 21 of the Code of Federal Regulations (CFR), section 210.3(b)(6) and 211.72.
Operating Pressure
- 4.5 bar (65 psi)
Pore Size
- 0.2 µm
Sample Type
- Aqueous
- Solvents
- Harsh liquids according to chemical compatibility
Sterilization Method
- Ethylene oxide
- Gamma irradiation
- Autoclave
Sterilization Procedures
- Ethylene oxide
- Gamma irradiation
- Autoclave, 121°C, 30 min
Total Throughput
- Up to 15 mL
Wettability
- Hydrophilic
pH Range
- 3.0 – 14.0
Application Area
- Analytical Sample Preparation
- Clarification
Filter Diameter
- ⌀ 15 mm
Filter Paper/Membrane Color
- White (opaque)
Application
- HPLC
- LCMS
- ICPMS
- Buffer & Media
Biosafety
- All materials of this filter element meet the requirements of the current USP Biological Reactivity tests for plastics Class VI (Systemic Injection, Intracutaneous and Implantation tests).
Cytotoxicity
- According to ISO 10993-5
Extractables
- HPLC certified
Pack Size
- 50
Packaging
- Bulk pouch packed