Lab Gel Electrophoresis Power Supply, Servicebio
รหัสสินค้า : SPW-6S
ราคา |
0.00 ฿ |
จำนวนที่จะซื้อ | |
ราคารวม | 0.00 ฿ |
สินค้าไม่เพียงพอ
สินค้าหมด
Lab Gel Electrophoresis Power Supply
Product Overview
This product is a rectifier device that converts alternating current to direct current. It can convert alternating current to controllable constant voltage and constant current to meet the needs of electrophoresis and other experiments. It is widely used for nucleic acid gel electrophoresis, protein gel electrophoresis, Western Blot protein transfer, and other experiments in biological and medical fields.
Product advantages
1. It can be fine tuned in real time under the working state.
2. Intelligent PID control, stable and reliable output;
3. HD LCD screen can display setting parameters, display real-time voltage, and current value;
4. High precision;
5. With constant voltage timing, constant current timing, gradient voltage programming, gradient current programming, and other working modes;
6. Using forward switching power supply design, good stability. With over voltage, over current, overload, variable load, no-load protection, abnormal automatic alarm protection;
7. can dynamically set the output voltage or current upper limit;
8. The parameters can be power off memory, equipment accident power after the power can automatically run the unfinished setting program.
2. Product advantages
1. It can be fine tuned in real time under the working state.
2. Intelligent PID control, stable and reliable output;
3. HD LCD screen can display setting parameters, display real-time voltage, and current value;
4. High precision;
5. With constant voltage timing, constant current timing, gradient voltage programming, gradient current programming, and other working modes;
6. Using forward switching power supply design, good stability. With over voltage, over current, overload, variable load, no-load protection, abnormal automatic alarm protection;
7. can dynamically set the output voltage or current upper limit;
8. The parameters can be power off memory, equipment accident power after the power can automatically run the unfinished setting program.
Technical parameters
1. Input power supply: 180V-240V
2. AC frequency: 50Hz/60Hz
3. Ambient temperature: 4C-40°C
4. Environmental humidity: 10%-70%
5. Output quantity: positive, negative pole A/B four groups
6. Output range: voltage 6V-600V(accuracy 1V); 5 mA - 600 mA (precision of 1 mA)
7. Control accuracy: voltage setting <100V, voltage stability accuracy <1V;
>100V, voltage stability accuracy <±1%
Current setting <100mA, current stability accuracy <1mA;
>100mA, current stability accuracy <±1%
8. Rated output power: 300W
9. L*W*H (mm): 265×215×120