ONE-Glo(TM) + Tox Luciferase & Cell Viability Assay, 1 Plat ยี่ห้อ Promega (Stroge. Temp -30C TO -10C)
รหัสสินค้า : E7110
ราคา |
0.00 ฿ |
จำนวนที่จะซื้อ | |
ราคารวม | 0.00 ฿ |
ONE-Glo™ + Tox Luciferase Reporter and Cell Viability Assay
Sensitive Detection of Reporter Activity and Cell Health
- Measures cell viability and firefly luciferase activity in the same assay well
- Easy to use—simply add reagent, mix and read
- Scalable to meet throughput needs, up to 1,536-well format
Understand Reporter Gene Activity in the Context of Cell Viability
The ONE-Glo™ + Tox Assay combines luciferase assay chemistry with a cell viability marker to better understand reporter gene expression in the context of cell health. The assay uses a two-step, addition-only process to make these measurements in a single well of a plate, negating the need to run parallel assays. The simple "add-mix-read" assay format and optimized reagents combine to create a flexible, automation-friendly assay that can be scaled to meet your needs.
Step 1: Cell Viability Assay
In the first part of the assay, a nonlytic fluorescence-based method (CellTiter-Fluor™ Cell Viability Assay) is used to measure the relative number of live cells in culture. The CellTiter-Fluor™ Assay measures a conserved and constitutive protease activity within living cells. This live-cell protease activity is restricted to intact viable cells and is measured using a fluorogenic, cell-permeant peptide substrate (glycylphenylalanyl-aminofluorocoumarin; GF-AFC). The substrate enters intact cells where it is cleaved by the live-cell protease to generate a fluorescent signal proportional to the number of living cells. The live-cell protease becomes inactive upon loss of cell membrane integrity and leakage into the surrounding culture medium. Fluorescence of the free AFC fluorophore is measured with a microplate reader or CCD imager using an excitation wavelength of 380–400nm and emission wavelength of 505nm.
Step 2: ONE-Glo™ Luciferase Assay
The second part of the assay uses the ONE-Glo™ Luciferase Assay System to quantify firefly luciferase gene expression from cells expressing the reporter. Ideally suited for high- and ultrahigh-throughput applications, the ONE-Glo™ Assay Reagent contains a fluoroluciferin substrate that gives increased stability and greater tolerance of sample components, and has less odor than standard luciferase assay reagents. Luminescence is measured with a microplate reader or CCD imager.
Reference
Niles, A.L. et al. (2007) A homogeneous assay to measure live and dead cells in the same sample by detecting different protease markers. Anal. Biochem. 366, 197–206.
ItemPart #Size
ONE-Glo™ Luciferase Assay Buffer
E605A1 × 10ml
ONE-Glo™ Luciferase Assay Substrate
E606A1 × 1 vial
GF-AFC Substrate
G608A1 × 10μl
Assay Buffer
G610A1 × 10ml
สินค้าไม่เพียงพอ
สินค้าหมด